Cold Room Solutions — Klang Valley

MICHODOOR Sliding Cold Room Doors

Premium MTLdoor-certified insulated sliding doors for commercial cold rooms, blast freezers, and chiller rooms. Professional supply & install by Micho Construction & Tech.

MS ISO/IEC 17021:2011 ISO 9001:2008 Supply & Install Puchong · Selangor
Cold room sliding doors installation
Large industrial cold room sliding door
Cold room door with overhead rail system
100mm
PU Foam Insulation
-30°C
Freezer Rated
3 Series
Solid / Superior / Smooth

Built for Malaysian Cold Chain Demands

Micho Construction & Tech supplies and installs MTLdoor-certified cold room sliding doors throughout the Klang Valley and Selangor. We handle everything from site measurement to final commissioning.

Whether you need a chiller at +4°C or a blast freezer at -30°C, we source and install the correct door series, seal system, and frame profile for your cold room panel layout.

Request Site Visit

Full Insulation Integrity

High-density PU foam core with perimeter gasket sealing minimises thermal bridging in both chiller and freezer applications.

🔒

Safety-First Design

Inner emergency release lock (80295) and inner emergency door pull (80290) ensure personnel are never trapped inside the cold room.

Anti-Freeze Heater Channel

Floor heater channel prevents ice build-up at the door sill — critical for freezer rooms below -15°C in Malaysia's humid climate.

📐

Custom Sizing Available

Standard sizes from 4′×7′ up to 10′×10′, plus special extra-height configurations for high-rack warehouse operations.

Three Door Series

All series feature sliding leaf design, PU foam insulation core, and perimeter gasket sealing.

Series 1SOLID
Solid Series

Workhorse cold room sliding door for standard chiller and freezer rooms. Flat panel design with heavy-duty overhead rail and adjustable nylon fibre pulleys.

ApplicationChiller / Freezer
Panel SurfaceFlat / Solid
Track TypeOverhead Rail
Side ClearanceMin 280mm
Series 2SUPERIOR
Superior Series

Enhanced door with recessed frame detailing. Popular for food processing facilities and pharmaceutical cold stores requiring a cleaner finish.

ApplicationFood / Pharma
Panel SurfaceFramed Profile
Track TypeOverhead Rail
Side ClearanceMin 280mm
Series 3SMOOTH
Smooth Series

Premium flush-surface door with no exposed fasteners. Ideal for HACCP-compliant facilities and high-hygiene clean-room environments.

ApplicationCleanroom / HACCP
Panel SurfaceFlush / Seamless
Track TypeOverhead Rail
Side ClearanceMin 280mm

Installation Manual Diagrams

Official MTLdoor Installation Manual Version 4.0. Click any diagram to view full size. Use tabs to navigate between pages.

Manual 1 — Door Frame Installation Layout
Manual 1 — 门洞安装指引 | Rail Track Support Installation LayoutMin side wall clearance: 280mm (11″). Min top clearance to ceiling: 345mm (13.5″) for rail + support. Travel space = Clear Opening Width + 430mm. Rail Track (80249) and Support Bracket (80261).
Manual 2 — Door Frame Front/Back/Isometric
Manual 2 — 门扇安装指引 | Door Frame Front, Back & Isometric ViewNumbered installation sequence (1–12). Floor heater channel detail with J-bracket (80305), L-bracket (80306), heater channel (80255). Aluminium angle profiles (80252–80257). Frame width = W + 130mm each side.
Manual 3 — Door Leaf Left View
Manual 3 — 门扇左侧图 | Door Leaf Left ViewComponent heights: External handle (80287) at 530mm, Inner emergency door pull (80290) at 1200mm, Inner emergency release lock (80295) at 1290mm. Adjustable nylon fibre pulley ø75mm (80281/80282). Total height reference: 1685mm.
Manual 4 — Door Leaf Right View
Manual 4 — 门扇右侧图 | Door Leaf Right ViewDoor leaf C-capping (80307–80310 for timber-free leaf). Gasket channel (80258). Aluminium angle profiles (80253/80254/80256/80257 for timber frame). Door guide wall type (80267). Bottom gasket assembly: aluminium profile (80253) + 2× gasket (80301).
Manual 5 — Door Leaf Back View
Manual 5 — 门扇后方图 | Door Leaf Back ViewArch channels: timber-free (80276TF) and timber frame (80276). Inner deep set door pull (80270). C-capping (80307–80310). Gasket (80302) + U-capping (80259). Inner emergency door pull (80290) assembly. Key heights: 980mm, 1200mm, 1290mm from floor.
Manual 6 — Completed Installation Front & Side View
Manual 6 — 门洞及门扇安装指引 | Completed Installation Front & Side ViewStriker positions from floor: 350mm, 1060mm, 1200mm, 1290mm, 1685mm. Side view depth: H + 246mm total. Wall panel depth: 146mm. Door guide (80267) and guide track (80251). Adjustable pulley (80281/80282).
Manual 7 — Special Height Door Layout
Manual 7 — 超高门扇安装指引 | Special Height Door InstallationExtra-tall door configuration with additional upper closure striker + hook (80268), external handle striker (80266), emergency handle striker (80265), lower closure striker + hook (80268). Door guide (80267) and track (80251). Total special height reference: 2085mm.
Dimensions Chart
门扇及门洞尺寸对比图 | Door Leaf & Door Opening Dimensions ChartComplete sizing for all standard configurations. Door width is wider than opening by 90mm (3½″). Door height is taller than opening by 19mm (¾″). *4′ actual = 1200mm  |  #8′ actual = 2400mm. Sizes from 4′×7′ up to 10′×10′.

Door Leaf & Opening Dimensions

Door leaf dimensions are larger than the clear opening — width is wider by 90mm (3½″) and height is taller by 19mm (¾″) to achieve full gasket compression and airtight sealing.

Installation Clearance Requirements: Min side wall clearance = 280mm (11″). Min top clearance (opening to ceiling) = 345mm (13.5″) for rail + support. Travel space = Clear Opening Width + 430mm minimum.
Door WidthDoor HeightOpening WidthOpening Height
4′ (1200mm)*7′ (2134mm)43¾″ (1112mm)83¼″ (2115mm)
5′ (1524mm)7′ (2134mm)56½″ (1434mm)83¼″ (2115mm)
5′ (1524mm)8′ (2438mm)56½″ (1434mm)95¼″ (2419mm)
6′ (1829mm)8′ (2438mm)68½″ (1739mm)95¼″ (2419mm)
6′ (1829mm)9′ (2743mm)68½″ (1739mm)107¼″ (2724mm)
6′ (1829mm)10′ (3048mm)68½″ (1739mm)119¼″ (3029mm)
7′ (2134mm)9′ (2743mm)80½″ (2044mm)107¼″ (2724mm)
7′ (2134mm)10′ (3048mm)80½″ (2044mm)119¼″ (3029mm)
8′ (2400mm)#10′ (3048mm)91″ (2311mm)119¼″ (3029mm)
9′ (2743mm)10′ (3048mm)104½″ (2653mm)119¼″ (3029mm)
10′ (3048mm)10′ (3048mm)116½″ (2958mm)119¼″ (3029mm)

* Actual door width for 4′ = 47¼″ (1200mm)  |  # Actual door width for 8′ = 94½″ (2400mm)

Key Components

All components are factory-supplied with each MichoDOOR unit. Replacement parts available through Micho.

80249 / 80261
Rail Track & Support Bracket
Overhead rail track with support bracket. Marking tool used to position screw holes precisely on the PU panel.
80281 (R) / 80282 (L)
Adjustable Nylon Fibre Pulley
ø75mm pulleys that hang and slide the door leaf on the overhead rail. Height-adjustable for level alignment.
80302
Door Leaf Gasket
Perimeter compression gasket ensuring airtight seal between door leaf and frame on all four sides.
80301
Door Leaf Bottom Gasket
Bottom sweep gasket on aluminium angle profile (80253). Seals the floor gap when door is fully closed.
80258 / 80259
Gasket Channel & U-Capping
Door leaf gasket channel and U-capping that retains and protects the perimeter gasket profile.
80267 / 80251
Door Guide & Track – Wall Type
Wall-mounted lower guide and track keeping the door leaf straight and preventing lateral movement.
80287
External Handle
Heavy-duty exterior door handle for pulling the door closed from outside the cold room.
80298
Articulated External Pull
Folding external pull handle that retracts flush when door is open, preventing passageway obstruction.
80270
Inner Deep Set Door Pull
Recessed interior pull handle for operating the door from inside the cold room.
80290
Inner Emergency Door Pull
Interior pull bar at 1200mm height allowing personnel to open the door from inside — essential safety requirement.
80295
Inner Emergency Release Lock
Mechanical override at 1290mm allowing anyone trapped inside to unlock and open the door independently.
80268
Closure Strikers (Upper/Lower)
Strike plates at upper and lower door edge holding the door firmly closed against gasket pressure.
80266 / 80265
Handle & Emergency Strikers
Strike plates on the door frame aligned with the external handle latch and emergency handle positions.
80255 / 80305–80306
Floor Heater Channel
Electric heating element preventing ice formation at the door sill — mandatory for rooms below -10°C.
80276 / 80276TF
Arch Channel (R & L)
Top arch channel for timber frame (80276) or timber-free (80276TF) door leaf configurations.
80307–80310
Door Leaf C-Capping
C-profile edge capping for timber-free door leaves, protecting all four panel edges.

Professional Supply & Install

Micho's cold room team handles the full installation from site measurement to client handover.

01
Site Survey & Measurement
We measure clear opening (W × H), verify ceiling clearance (min 345mm above opening), and confirm side wall clearance (min 280mm) before placing order.
02
Rail Track & Support Installation
Overhead rail track (80249) installed using marking tool and support brackets (80261) secured to the PU panel or structural beam above the opening.
03
Frame & Heater Channel Fitting
Aluminium angle profiles, floor heater channel with J/L-brackets, and gasket channels fitted to the door opening before the door leaf is hung.
04
Door Leaf Hanging & Alignment
Door leaf hung on adjustable nylon pulleys and levelled. Bottom guide channel (80267) fitted to prevent lateral movement during operation.
05
All Hardware Fitting
External handle, articulated pull, inner emergency pull (80290), emergency release lock (80295), and all closure strikers fitted and adjusted.
06
Seal Check & Commissioning
Perimeter gasket compression verified, floor heater channel tested, door operation demonstrated to client before sign-off and handover.

NEED A COLD ROOM DOOR?

Get a no-obligation quotation for supply and installation in Klang Valley & Selangor.

WhatsApp Us Now